Master Lock B100, B30, B70 Air Output, Air Intake, and Lint Filters, Pump Pressure, Adjustment

Models: B100 B70 B150 B30

1 32
Download 32 pages 21.61 Kb
Page 14
Image 14
Air Output, Air Intake,

 

 

Air Intake Filter

 

Air Output, Air Intake,

Filter End

 

and Lint Filters

 

Cover

Fan Guard

1.

Remove upper shell (see

 

 

 

 

page 10).

 

 

2.

Remove filter end cover

 

 

 

screws using 5/16" nut-

 

 

 

driver.

Lint Filter

 

3.

Remove filter end cover.

 

Air Output

 

4.

Replace air output and lint

 

Filter

 

 

filters.

 

 

 

 

5.

Wash or replace air intake

 

 

 

filter (see Preventative

 

 

 

Maintenance Schedule,

Figure 20 - Air Output, Air Intake, and Lint Filters,

 

page 8).

30/70,000 BTU/Hr Models

 

6.

Replace filter end cover.

Air Intake Filter

Fan Guard

7.

Replace fan guard and

 

(90,000 BTU/Hr

 

upper shell.

Filter End

Model Shown)

IMPORTANT: Do not oil

Cover

 

 

 

filters

 

 

 

 

Lint Filter

 

 

 

 

Air Output

 

 

 

Filter

 

Figure 21 - Air Output, Air Intake, and Lint Filters,

 

 

90/150,000 BTU/Hr Models

Pump Pressure

 

 

 

Adjustment

 

 

(30/70,000 BTU/Hr Models Shown)

1. Remove pressure gauge

 

 

 

 

 

plug from filter end cover.

Pressure

 

Relief

2. Install accessory pressure

 

Gauge

 

Valve

gauge (part number

 

Plug

 

 

HA1180).

 

 

 

 

 

3. Start heater (see Operation,

 

 

 

page 7). Allow motor to

PRESSURE GAUGE PLUG

PFA/OV 006B

reach full speed.

Figure 22 - Pressure Gauge Plug Removal

 

 

 

4. Adjust pressure. Turn relief

 

 

 

valve to right to increase

 

 

 

pressure. Turn relief valve

 

 

Pressure

to left to decrease pressure.

 

Pump

 

Gauge

See specifications at right

Model

 

Pressure

for correct pressure for

30,000 BTU/Hr

2.6 PSI

 

each model.

70,000 BTU/Hr

3.8 PSI

 

5. Remove pressure gauge.

90,000 BTU/Hr

4.4 PSI

 

Replace pressure gauge

150,000 BTU/Hr

4.9 PSI

 

plug in filter end cover.

 

 

Figure 23 - Adjusting Pump Pressure

 

 

 

14

100743

Page 14
Image 14
Master Lock B100, B30, B70, B150 Air Output, Air Intake, and Lint Filters, Pump Pressure, Adjustment, filter see Preventative