Master Lock B150, B30, B70, B100 owner manual Specifications, IMPORTANT Remove fan

Models: B100 B70 B150 B30

1 32
Download 32 pages 21.61 Kb
Page 19
Image 19
IMPORTANT: Remove fan

Fan

 

 

IMPORTANT: Remove fan

 

 

from motor shaft before

 

 

removing motor from heater.

 

 

The weight of the motor

Setscrew

Fan

resting on the fan could

 

 

damage the fan pitch.

 

 

1. Remove upper shell (see page 10).

2.Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft.

3.

Slip fan off motor shaft.

Motor

4.

Clean fan using a soft cloth

Shaft

 

 

 

 

 

moistened with kerosene or

 

 

 

 

 

solvent.

 

 

 

 

5.

Dry fan thoroughly.

Figure 35 - Fan, Motor Shaft, and Setscrew Location

6.

Replace fan on motor

 

 

 

 

 

shaft. Place fan hub flush

 

 

 

 

 

with end of motor shaft

 

 

 

 

 

(see Figure 36).

 

 

 

 

7.

Place setscrew on flat of

Fan

 

shaft. Tighten setscrew

 

firmly (40-50 inch-pounds/

 

 

 

 

 

 

 

 

 

 

4.5-5.6 n-m).

 

 

 

 

8.

Replace fan guard and

 

 

 

 

 

upper shell.

 

 

 

Flush

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

Shaft

 

 

Setscrew

 

Figure 36 - Fan Cross Section

 

SPECIFICATIONS

Output Rating (BTU/Hr)

30,000

70,000

90,000

150,000

 

Fuel

Use Only Kerosene or Paraffin

 

 

Fuel Tank Capacity

 

 

 

 

 

(U.S. Gal./Liters)

3.0/11.35

5.0/18.92

9.0/34.06

13.5/51.09

 

Fuel Consumption

 

 

 

 

 

(Gal. Per Hr./Liters Per Hr.)

.23/.87

.49/1.85

.66/2.5

1.10/4.16

 

Electric Requirements

240 V/50 Hz (Same All Models)

 

 

Amperage (Normal Run)

.8

1.0

1.58

1.5

 

Hot Air Output (CFM/CMM)

140/3.96

225/6.36

425/12

600/17

 

RPM

1425

2850

2850

2850

19