Fan |
|
| |
IMPORTANT: Remove fan |
|
| |
from motor shaft before |
|
| |
removing motor from heater. |
|
| |
The weight of the motor | Setscrew | Fan | |
resting on the fan could | |||
|
| ||
damage the fan pitch. |
|
|
1. Remove upper shell (see page 10).
2.Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft.
3. | Slip fan off motor shaft. | Motor | |||
4. | Clean fan using a soft cloth | Shaft | |||
|
|
|
| ||
| moistened with kerosene or |
|
|
|
|
| solvent. |
|
|
|
|
5. | Dry fan thoroughly. | Figure 35 - Fan, Motor Shaft, and Setscrew Location | |||
6. | Replace fan on motor |
|
|
|
|
| shaft. Place fan hub flush |
|
|
|
|
| with end of motor shaft |
|
|
|
|
| (see Figure 36). |
|
|
|
|
7. | Place setscrew on flat of | Fan | |||
| shaft. Tighten setscrew | ||||
| firmly |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| |
8. | Replace fan guard and |
|
|
|
|
| upper shell. |
|
|
| Flush |
|
|
|
| ||
|
|
|
|
| |
|
|
|
|
|
|
|
| Motor | |||
|
| Shaft | |||
|
| Setscrew |
| Figure 36 - Fan Cross Section |
| |||
SPECIFICATIONS | Output Rating (BTU/Hr) | 30,000 | 70,000 | 90,000 | 150,000 |
| Fuel | Use Only Kerosene or Paraffin |
| ||
| Fuel Tank Capacity |
|
|
|
|
| (U.S. Gal./Liters) | 3.0/11.35 | 5.0/18.92 | 9.0/34.06 | 13.5/51.09 |
| Fuel Consumption |
|
|
|
|
| (Gal. Per Hr./Liters Per Hr.) | .23/.87 | .49/1.85 | .66/2.5 | 1.10/4.16 |
| Electric Requirements | 240 V/50 Hz (Same All Models) |
| ||
| Amperage (Normal Run) | .8 | 1.0 | 1.58 | 1.5 |
| Hot Air Output (CFM/CMM) | 140/3.96 | 225/6.36 | 425/12 | 600/17 |
| RPM | 1425 | 2850 | 2850 | 2850 |
19