MINIMUM BURNER SETTING ADJUSTMENT

Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position. If some ports do not light, increase the minimum gas rate setting.

Check whether the burner remains lit even when the gas tap is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.

The procedure for adjusting the minimum gas rate setting is described below.

using a screwdriver turn screw “A” until the flame setting is correct (fig. 11).

Auxiliary, Semi-rapid and Rapid burner

Normally for ULPG fully tighten the adjustment screw.

Triple-ring burner (only for the models DEGH70BG, DEGH90BG)

Normally for ULPG fully tighten the adjustment screw, then turn the screw 3/8 anti- clockwise.

LUBRICATING THE GAS TAP

If a gas tap is difficult to turn, disassemble it, clean it carefully with petrol and spread a little high-temperature-resistant grease on it.

These operations must be performed by an Authorized person/Service agent. Note: Servicing of this appliance is only to be carried out by Authorised Person.

Figure 11

A

15

Page 15
Image 15
DeLonghi DEGH60BG, DEGH70BG, DEGH90BG manual Minimum Burner Setting Adjustment, Lubricating the GAS TAP