CLEARANCES
Installation clearances and protection of combustible surfaces shall comply with the current local regulations e.g. AS/NZS5601 - Gas Installations code.
Model: DEGH60BG |
|
|
| Model: DEGH70BG | ||
585 |
|
|
|
|
| 715 |
510 |
|
| (3) | 510 |
|
|
|
| (2) |
|
|
| |
| 60 |
| (1) |
|
| |
(1) |
|
|
|
| ||
54 |
|
|
| 54 |
|
|
480 |
|
|
|
|
| 480 |
560 |
|
|
|
|
| |
|
|
| 560 |
|
| |
|
|
|
|
|
| |
Figure 3a |
|
|
| Figure 3b |
|
|
| Model: DEGH90BG |
|
| |||
510 |
|
|
| 869 |
|
|
|
|
|
|
|
| |
(1) |
|
|
|
| (2) | (3) |
|
|
| 60 |
| ||
54 |
|
|
|
|
| |
| 840 |
| 480 |
|
| |
|
|
|
|
| ||
Figure 3c |
|
|
|
|
|
|
60
(2) | (3) |
|
(1)54 mm from top of countertop.
(2)At least 60 mm between the back side of the
(3)At least 200 mm from the periphery of the nearest burner to any vertical combustible surface. If the distance from the periphery of the nearest burner to any vertical combustible surface, or vertical combustible surface with toughened glass or sheet metal, is less than 200 mm, the surface shall be protected (in accordance with AS/NZS5601) to a height of not less than 150 mm above the hob for the full dimension (width or depth) of the cooking surface area.
Important note:
This appliance shall not be used as a space heater, especially if installed in marine craft or caravans.