The installation shall comply with the dimensions in Figures 3a, 3b or 3c and 4a, 4b or 4c, bearing in mind that:
■■ A partition between the base of the hob and the cupboard below should be fitted 30
mmbelow the workbench surface if the cupboard is to be used for storage.
■■ If the hob is installed over a
■■ Overhead clearances - In no case shall the clearance between the highest part of the hob and a range hood be less than 600 mm, or for an overhead exhaust fan 800 mm. Any other downward facing combustible surface less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with local regulations inforce. However, in no case shall this clea- rance to any surface be less than 450 mm.
Standards requirement
Temperature of nearby surfaces. Australian and New Zealand Gas Installation Stan- dards (AS/NZS5601) require a cooktop to be installed so that the surface temperature of any nearby combustible surface will not exceed 65°C above ambient.
This is typically achieved by:
■■ having the cooktop spaced away from the wall (see figures 3a, 3b or 3c and 4a, 4b or 4c);
AND
■■ protecting the wall to a height of at least 150 mm along its length (minimum height of
––5
––tempered glass or sheetmetal, minimum thickness 0.4 mm (acceptable when used in front of a fire resistant material).
INSTALLING THE SEPARA- TOR BELOW THE BASE OF THE COOKTOP
It is recommended that a 30 mm clearance be left between to base of the cooktop and the separator.
The separator shall be heat resi- stant, made of low thermal con- ductivity material and shall be re- movable with the use of a tool for installation and service.
| Figure 5 | |
Clearance | 30 mm | |
Separator | ||
| ||
Space for |
| |
connections |
| |