CONVERSION PROCEDURE (to convert to Natural gas or to ULPG)

REPLACING THE INJECTORS

The conversion procedure must be carried out only by an authorised person.

This appliance is suitable for use with Natural gas or Universal LPG (check the “gas type” sticker attached to the appliance).

The nominal gas consumption and injector size details are provided in table at page 13.

To replace the injectors proceed as follows:

■■ Remove pan supports and burners from the cooktop.

■■ Using a spanner, remove the injector “J” (figs. 10a, 10b) and replace it with one accor- ding to the gas type (see table - page 13).

■■ Affix to the appliance the warning label stating that the cooktop has been converted for use with Natural gas/ULPG (supplied with the Natural gas/ULPG conversion kit). A second Natural gas/ULPG conversion label should also be affixed to an adjacent surface along with the duplicate data plate.

IMPORTANT

■■ If the cooktop is suitable for use with Natural gas and must be converted for use with Universal LPG, before connecting to gas main remove the appliance gas regulator and replace with test point adaptor (see figs. 8a, 8b).

■■ If the cooktop is suitable for use with Universal LPG and must be converted for use with Natural gas, before connecting to the gas main remove the appliance test point adaptor and replace with gas regulator (see figs. 8a, 8b).

NOTE:

Gas regulator and test point adaptor are supplied with the appliance (packed with conver- sion kit).

The burners are designed so that regulation of primary air is not required.

J

Only for the models with triple-ring burner (DEGH70BG, DEGH90BG)

J

Figure 10a

Figure 10b

14

Page 14
Image 14
DeLonghi DEGH90BG, DEGH60BG, DEGH70BG manual Replacing the Injectors