MINIMUM BURNER SETTING ADJUSTMENT

Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position. If some ports do not light, increase the minimum gas rate setting.

Check whether the burner remains lit even when the gas tap is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.

The procedure for adjusting the minimum gas rate setting is described below.

Turn on the burner

Turn the tap to the MINIMUM position

Take off the knob

With a small flat screwdriver turn the screw “F” (fig. 9) to the correct regulation.

Normally for Propane gas, the regulation screw is tightened up.

Figure 9

F

12