GAS SUPPLY:
■The connection must be performed by an authorised person according to the relevant standards.
■Before connecting the appliance to the gas main, mount the brass conical adap- tor onto the gas inlet pipe, upon which the gasket has been placed (figs.
Conical adaptor and gasket are supplied with the appliance (packed with con- version kit for use with Natural gas or Propane gas).
■This appliance is suitable for use with Natural Gas or Propane gas. (Check the “gas type” sticker attached to the appliance).
■For Natural Gas models the gas supply is connected to the pressure regulator which is supplied with the appliance (fig. 5). Adjust the regulator to obtain a test point pressure of 1 kPa with the two
■For Propane gas models the gas supply is connected to the test point adaptor which is supplied with the appliance (fig. 4) and ensure that the supply pressure is regulated to 2.75 kPa.
■The connection must be made at the rear of appliance (left or right); the pipe does not cross the cooker.
■The inlet not used must be closed off with the cap and sealing gasket supplied.
■IMPORTANT: Use two spanners to tighten or loosen the connecting pipe (fig. 6)
Figure 4
Gas connection for
PROPANE GAS
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use suitable seal)
Test point adaptor
Test point
Figure 5
Gas connection for
NATURAL GAS
| Gas inlet pipe |
| Nipple |
| Gasket |
Test | Brass conical adaptor |
point | (Thread tight: use |
| suitable seal) |
Gas regulator
9