TABLE FOR THE CHOICE OF THE INJECTORS
| Natural gas | Propane gas | ||||
|
|
|
|
|
|
|
Test Point Pressure [kPa] |
| 1.0 |
| 2.75 | ||
| Injector |
| Gas | Injector |
| Gas |
BURNER | Orifice Dia. |
| Consumption | Orifice Dia. |
| Consumption |
|
|
|
|
|
| |
| [mm] |
| [MJ/h] | [mm] |
| [MJ/h] |
|
|
|
|
|
|
|
Auxiliary (A) | 0.85 |
| 3.60 | 0.53 |
| 3.60 |
|
|
|
|
|
|
|
1.12 |
| 6.30 | 0.70 |
| 6.30 | |
|
|
|
|
|
|
|
Triple ring (TC) | 1.65 |
| 13.30 | 0.95 |
| 11.90 |
|
|
|
|
|
|
|
LUBRICATION OF THE GAS TAPS
If the gas tap becomes stiff, it is necessary to dismantle it carefully and clean it with petroleum spirit. Specialist high temperature resistant grease should be used to lubricate the tap before replacing.
The operations must be carried out by an authorised person/service agent.