DeLonghi ESAM6600 manual Correct Incorrect, C o l l e c t i o n

Models: ESAM6600

1 25
Download 25 pages 14.88 Kb
Page 17
Image 17
CORRECT INCORRECT

Infuser

Push the PUSH symbol fully in until

Manual background it clicks into place.

After having heard the click, check that the red buttons have snapped out.

Support

 

Pin

 

Bottom pipe on the infuser. The pin must be inserted

 

 

 

 

into the bottom pipe on the infuser.

 

 

 

 

 

 

 

 

Check that the two red buttons have snapped out, otherwise the door cannot be closed.

The two red buttons have snapped out CORRECTLY Manual background

The two red buttons have not snapped out

CORRECT INCORRECT

Replace the drip tray, complete with the grounds container.

Close the service door.

NOTE 1: If the infuser is not inserted correctly, until it clicks into place, and the two red buttons have not snapped out, the service door cannot be closed.

NOTE 2: If it is hard to insert the infuser, before inserting it, squeeze it to the right size by pressing it forcefully from the top and bottom simultaneously, as shown in figure .

NOTE 3: If it is still hard to insert the infuser, leave it out of the appliance, close the service door, unplug from the outlet then plug in again. Wait for all the lights to go off, after the diagnostics, then open the door and replace the infuser.

 

16

 

 

C o l l e c t i o n

 

 

 

Page 17
Image 17
DeLonghi ESAM6600 manual Correct Incorrect, C o l l e c t i o n