1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Place propane/LP sup- ply tank(s) outdoors.

3.This heater shall not be installed in a bed- room or bathroom.

4.If you smell gas

-Shut off gas supply

-Do not try to light any appliance.

-Do not touch any electrical switch; do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

-If you cannot reach your gas supplier, call the fire department.

5.Always run heater with plaque control knob 1,2,3 or at the 1,2, or 4 locked posi- tions, Never set control knob between locked positions. Poor combustion and higher levels of carbon of monoxide may result.

6.This heater needs fresh, outside air ventila- tion to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for combustion and Ventilation, pages 4 through.

7.If heater shut off, do not light again until you provide fresh, outside air. If heater keeps shutting off, have it service.

8.Do not run heater

-where flammable liquids or vapors are used or stored

-under dusty conditions

9.Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the con- trol system and any gas control which has been under water.

10.Turn off and unplug heater and let cool before servicing. Only a qualified service

person should service and repair heater.

11.Operating heater above elevations of 4,500 feet could cause power outage.

12.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

13.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.

14.Provide adequate clearances around air openings.

LOCAL CODES

Install and use heater with care. Follow all local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*

* Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY10018

National Fire Protection, Inc

Batterymarch Park

Quincy, MA 02269

PRODUCT IDENTIFICATION

Fig.1

UNPACKING

1.Remove the heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly inform deal- er where you bought heater.