Delta 11-990 Magnetic Base Lamp, Starting and Stopping Drill Press, Locking Switch OFF Position

Models: 11-990

1 15
Download 15 pages 50.56 Kb
Page 11
Image 11

OPERATING CONTROLS AND ADJUSTMENTS

MAGNETIC BASE LAMP

The magnetic base lamp operates independently from the drill press. To turn the lamp “ON” and “OFF”, rotate switch (B) Fig. 20.

STARTING AND STOPPING DRILL PRESS

The switch (A) Fig. 21, is located on the front of the drill press head. To turn the drill press “ON” move the switch to the up position. To turn the drill press “OFF” move the switch to the down position.

A

Fig. 21

LOCKING SWITCH IN

THE “OFF” POSITION

IMPORTANT: When the tool is not in use, the switch should be locked in the “OFF” position to prevent unauthorized use. This can be done by grasping the switch toggle (B) and pulling it out of the switch, as shown in Fig. 22. With the switch toggle (B) removed, the switch will not operate. However, should the switch toggle be removed while the drill press is operating, the switch can be turned “OFF” once, but cannot be restarted without inserting the switch toggle (B).

TABLE ADJUSTMENTS

1.The table can be raised or lowered on the drill press column by loosening the table clamp handle (A) Fig. 23, and turning the table raising and lowering handle (B) Fig.

24.After the table is at the desired height, tighten handle

(A) Fig. 23. NOTE: Final positioning of the drill press table should always be from the bottom to the up position.

2.The table can be rotated 360 degrees on the column by loosening clamp handle (A) Fig. 23, rotate table to desired position and tighten clamp handle (A).

B

Fig. 22

A

Fig. 23

B

Fig. 24

11

Page 11
Image 11
Delta 11-990 Magnetic Base Lamp, Starting and Stopping Drill Press, Locking Switch OFF Position, Table Adjustments