Delta 36-465 instruction manual Extension Cords

Models: 36-465

1 36
Download 36 pages 51.91 Kb
Page 6
Image 6
EXTENSION CORDS

3.Grounded, cord-connected tools intended for use on a supply circuit having a nominal rating between 150 -

250volts, inclusive:

If the tool is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. C. The tool will have a grounding plug that looks like the plug illustrated in Fig. C. Make sure the tool is connected to an outlet having the same configuration as the plug. No adapter is available or should be used with this tool. If the tool must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel; and after reconnection, the tool should comply with all local codes and ordinances.

Manual background IN ALL CASES, MAKE CERTAIN THE R E C E P TA C L E I N Q U E S T I O N I S P R O P E R LY GROUNDED . IF YOU ARE NOT SURE HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.

GROUNDED OUTLET BOX

CURRENT CARRYING PRONGS

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

Fig. C

EXTENSION CORDS

Manual background Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows the correct gauge to use depending on the cord length and voltage. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

120 VOLT MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

 

 

 

 

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

Fig. D-1

230 VOLT MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

 

 

 

 

0-6

230

up to 50

18 AWG

0-6

230

50-100

16 AWG

0-6

230

100-200

16 AWG

0-6

230

200-300

14 AWG

6-10

230

up to 50

18 AWG

6-10

230

50-100

16 AWG

6-10

230

100-200

14 AWG

6-10

230

200-300

12 AWG

10-12

230

up to 50

16 AWG

10-12

230

50-100

16 AWG

10-12

230

100-200

14 AWG

10-12

230

200-300

12 AWG

12-16

230

up to 50

14 AWG

12-16

230

50-100

12 AWG

12-16

230

GREATER THAN 100 FEET NOT RECOMMENDED

Fig. D-2

6

Page 6
Image 6
Delta 36-465 instruction manual Extension Cords