Delta 50-764, 50-765 instruction manual Attaching Dust Collection BAG, Using Metal BAG Clamp

Models: 50-764 50-765

1 48
Download 48 pages 32.58 Kb
Page 11
Image 11

ATTACHING DUST COLLECTION BAG

DISCONNECT MACHINE FROM

POWER SOURCE

USING CLOTH COVERED FLEXIBLE RING:

1.Take cloth-covered bag retainer ring (A) Fig. 8 and place it inside opening of clear plastic dust col- lection bag. Fold about 6 inches of the bag down around the retainer ring.

2.Place bag up into the motor/blower assembly (B) Fig. 8 and fit retainer ring (A) Fig. 8 and (A) Fig. 9 into bottom groove (B) Fig. 9. It will be necessary to bend and fold the ring to fit it into place.

3.Tug slightly on bag to eliminate any slack and to make sure there is a good fit so the bag will not detach during collection.

4.Repeat for other bag.

USING METAL BAG CLAMP:

The plastic bag can also be attached to the outside of the dust collector using the included clamp (B) Fig. 10:

1.Place clamp (B) around top of plastic bag (A) and fold about 4 to 6 inches of plastic bag over the clamp as show in Fig. 10.

2.Place the clamp and plastic bag assembly (A) Fig. 10A and fasten clamp securely as shown.

3.Repeat for other bag.

A

B

Fig. 8

A

B

Fig. 9

B

A

Fig. 10

B

A

Fig. 10A

11

Page 11
Image 11
Delta 50-764, 50-765 instruction manual Attaching Dust Collection BAG, Using Metal BAG Clamp