ATTACHING ACCESSORY HOSE TO INTAKE PORT

DISCONNECT MACHINE FROM POWER SOURCE BEFORE CONNECTING OR

DISCONNECTING HOSE .

Models 50-764/50-765 provides four 5” dust ports. Pro- ceed as follows for each port with your accessory hos- es.

NOTE: Place open end (D) of intake cap rings around and onto ends of each dust intake port before attaching the hose.

To assemble the 5” dust collection hose (not included) to the motor and blower assembly, loosely attach hose clamp (A) Fig. 13, around one end of flexible hose (B) and assemble the hose to dust intake port (C). Tighten hose clamp (A). Assemble the remaining clamp to the other end of the flexible hose and to the woodworking machine.

NOTE: See “ACCESORIES” section of this manual.

NOTE: Do not operate the dust collector with any of the holes in dust intake port (C) Fig. 13 uncovered. To cover a hole not being used by a hose, place the flat intake cap

(E) on dust intake port as shown in Fig. 13.

SINGLE AND THREE PHASE WIRING

C

D

E

A

B

Fig. 13

INSTALLATION BY A QUALIFIED ELECTRICIAN IS RECOMMENDED TO ASSURE SAFE AND PROP- ER WIRING AND PRODUCT OPERATION.

DISCONNECT POWER AT SOURCE BE- FORE WIRING THE MACHINE.

MODEL 50-764 THREE

PHASE INSTALLATION FOR 230 VOLTS

Your dust collector is supplied with a motor and a mag- netic starter controller and must be permanently con- nected to the building’s electrical system and grounded to meet code.

1.To connect the dust collector to a power system, re- move controller cover (A) Fig. 14.

2.Bring three phase power line through the access hole (B) Fig. 14, in the top of controller box and con- nect the three power lines to terminals (C) Fig. 15, and the green ground wire to ground screw (D).

Model 50-764

B

A

Model 50-765

B

A

BE SURE TO REINSTALL COVER BE- FORE OPERATING.

DO NOT INSERT FINGERS OR ANY FOR- EIGN OBJECT INTO THE DUST INTAKE PORT.

MAKE SURE UNIT IS PROPERLY GROUNDED.

Fig. 14

13

Page 13
Image 13
Delta 50-764, 50-765 instruction manual Attaching Accessory Hose to Intake Port, Single and Three Phase Wiring