Delta 50-861, 50-866 Connecting Machine to Power Source, Single Phase Installation

Models: 50-866 50-861

1 16
Download 16 pages 16.5 Kb
Page 12
Image 12

CONNECTING MACHINE TO POWER SOURCE

MODEL 50-866

SINGLE PHASE

INSTALLATION

WARNING: Installation by a qualified electrician is recommended to assure safe and proper wiring and product operation.

The motor rating for your single phase dust collector is 230 Volts, 5 H.P. Before connecting your dust collector to an electrical power system, be sure the electrical system agrees with the motor rating of the tool.

The single phase Model 50-866 Dust Collector is supplied with a motor and controller; however, it is not furnished with a power cord or plug. To connect the dust collector to a power system, proceed as follows:

1.Assemble the control box (A) Fig. 32, to the front of the side support (H) Fig. 33. Insert sheet metal screws

(B) Fig. 32, through holes in the controller box and thread the sheet metal screw into the side support and tighten securely.

2.Bring the power cord (not supplied) up through the large knockout hole (C) Fig. 32, in the control box (A) and connect the two power lines to terminals (D) and the green ground wire to ground screw (E). NOTE: THE

POWER CORD MUST BE INSERTED THROUGH THE BUSHING IN THE ACCESS HOLE (C), TIGHTEN THE ACCESS HOLE NUT OVER THE ACCESS HOLE TO HOLD THE POWER CORD IN PLACE.

3.Reassemble the cover onto the controller box (A) Fig. 33.

4.The ON/OFF buttons are located at the front of the control box. To start the machine, push “ON” button (F) Fig. 33. To stop the machine, push the “OFF” button (G).

B

D

D

E

B

A

C

Fig. 32

H

F

A

G

Fig. 33

12

Page 12
Image 12
Delta 50-861, 50-866 instruction manual Connecting Machine to Power Source, Single Phase Installation