WARNING: Installation by a qualified electrician is recommended to assure safe and proper wiring and product operation.

The motor rating for your three phase dust collector is 200-220/440 Volts, 5 H.P. Unless ordered special, the machine is shipped wired for 200-220 Volts. Before connecting your dust collector to an electrical power system, be sure the electrical system agrees with the motor rating of the tool. Your dust collector is supplied with a motor and controller; however, it is not supplied with a power cord and plug.

1.To connect the dust collector to a power system, remove controller cover (C) Fig. 35.

2.Bring the power cord through the access hole (B) Fig. 34, in the controller box, and connect the three power lines to terminals (D) and the green ground wire to ground screw (E). NOTE: THE POWER CORD MUST

BE INSERTED THROUGH THE BUSHING IN THE ACCESS HOLE (B), TIGHTEN THE ACCESS HOLE NUT OVER THE ACCESS HOLE TO HOLD THE POWER CORD IN PLACE.

3.After connecting the power cord to the machine, make certain the rotation of the motor is in the proper direction by viewing the rotation of the blower fan. The fan should rotate in a clockwise direction. CAUTION: DO

NOT INSERT FINGERS OR ANY FOREIGN OBJECT INTO THE DUST INTAKE PORT. Rotation of the motor can be reversed by interchanging any two of the three incoming power lines connected to terminals (D) Fig. 34. Replace controller cover (C).

4.The on/off buttons are located at the front of the control box (C) Fig. 35. To start the dust collector, push “ON” button (B). To stop the machine, push “OFF’” button

(D).

DUST INTAKE PORT CAPS

1.IMPORTANT: FOUR DUST INTAKE PORT CAPS ARE SUPPLIED WITH THE DUST COLLECTOR, AS SHOWN IN FIG. 36. THE CAPS ARE TO BE PLACED ONTO THE DUST INTAKE PORTS WHEN ALL OR ANY NUMBER OF THE PORTS ARE NOT IN USE.

WARNING:THE BLOWER HOUSING CONTAINS A HIGH SPEED RADIAL BLADE THAT CAN AMPUTATE F I N G E R S , G R A B L O O S E C L O T H I N G A N D NECKTIES, OR PROPEL DUST AT HIGH SPEEDS.

WARNING: D O N O T OPERATE THE MACHINE WITHOUT THE DUST CAPS OR BAGS IN PLACE.

WARNING:DO NOT INSERT FINGERS OR ANY FOREIGN OBJECT INTO THE DUST INTAKE PORTS. 2. Place the collar (B) Fig. 36, over the opening of the

B

D

E

Fig. 34

B

C

D

Fig. 35

C

B

Fig. 36

intake port. Press the recessed side of the cap into the port (C) opening. IMPORTANT: When connecting an intake hose to any of the intake ports, DO NOT REMOVE THE COLLAR (B) FIG. 36, FROM THE INTAKE PORT. Pull the dust cap from the port opening and push the collar and cap onto the port housing.