4.Remove the cleaning solution application tank from the application nozzle. a

5.Soap mixture pressure can be adjusted by adjusting the pipe located in the cleaning solution application nozzle (a).

a. Pull pipe (b) from cleaning solution application nozzle.

b

b.Position the notch (c) on the pipe to the desired soap mixture 1-6, 1 being the highest and 6 being the lowest.

c

c.Press pipe into position.

6.Fill application tank with detergent.

7.Push cleaning solution application tank onto cleaning solution application nozzle. Turn to lock into place.

8.See Before Starting and Starting Your Pressure Washer paragraphs in this section to continue.

D29382

10- ENG

Page 10
Image 10
Delta instruction manual D29382 ENG