For Ratio-Metric applications that need the PS1 and PS2 outputs arrive regulation set point at same time, use equation 1 to calculate R1, set V=Voset,PS1–Voset,PS2and V will be negative. The waveforms of power up and down are showed in Figures 7 and 8.

R1 =

[(Voset ,PS 2

+ ∆V ) − Vref ]

* 20K ------------------------------------------------------

(1)

 

Vref

 

 

 

 

 

Note:

1.Vref =0.4×Voset,PS2 , please refer to Table 5 for Vref set value.

2.V is the maximum difference of voltage between PS1 and PS2 supply voltage.

For example, the PS1 Voset,PS1=5V, the PS2 Voset,PS2=3.3V, R1 is calculated as follows:

R1 =

[(3.3 + 1.7) − 1.32]

* 20K = 55.75K

1.32

 

 

 

 

PS1=5V

+V=1.7V PS2=3.3V

PS1

PS2

Figure 7. Ratio–metric tracking Power up

Figure 8. Ratio–metric tracking Power down

For Ratio-Metric applications that need the PS2 supply voltage rises first at power up and falls second at power down, use equation 2 to calculate R1, set V0.4×Voset,PS2 and V will be negative. The waveforms of power up and down are showed in Figures 9 and 10.

R1 =

[(Voset , ps 2

− ∆V ) − Vref ]

* 20K -----------------------------------------------------------------

(2)

 

Vref

 

 

 

 

Note:

1.Vref =0.4×Voset,PS2 , please refer to Table 5 for Vref set value.

2.V is defined as the voltage difference between VoPS1 and VoPS2 when VoPS2 reaches its rated voltage.

13

Page 13
Image 13
Delta Electronics DNS SIP Series manual Vref, PS1=5V