For Ratio-Metric applications that need the PS1 and PS2 outputs arrive regulation set point at same time, use equation 1 to calculate R1, set V=Voset,PS1–Voset,PS2and V will be negative. The waveforms of power up and down are showed in Figures 7 and 8.

R1 =

[(Voset ,PS 2

+ ∆V ) − Vref ]

* 20K ------------------------------------------------------

(1)

 

Vref

 

 

 

 

 

Note:

1.Vref =0.4×Voset,PS2 , please refer to Table 5 for Vref set value.

2.V is the maximum difference of voltage between PS1 and PS2 supply voltage.

For example, the PS1 Voset,PS1=5V, the PS2 Voset,PS2=3.3V, R1 is calculated as follows:

R1 =

[(3.3 + 1.7) − 1.32]

* 20K = 55.75K

1.32

 

 

 

 

PS1=5V

+V=1.7V PS2=3.3V

PS1

PS2

Figure 7. Ratio–metric tracking Power up

Figure 8. Ratio–metric tracking Power down

For Ratio-Metric applications that need the PS2 supply voltage rises first at power up and falls second at power down, use equation 2 to calculate R1, set V0.4×Voset,PS2 and V will be negative. The waveforms of power up and down are showed in Figures 9 and 10.

R1 =

[(Voset , ps 2

− ∆V ) − Vref ]

* 20K -----------------------------------------------------------------

(2)

 

Vref

 

 

 

 

Note:

1.Vref =0.4×Voset,PS2 , please refer to Table 5 for Vref set value.

2.V is defined as the voltage difference between VoPS1 and VoPS2 when VoPS2 reaches its rated voltage.