Delta Electronics DNS SIP Series manual For DNS04xx series, Vtrim = 0.7 − 0.1698 ⋅ Vout

Models: DNS SIP Series

1 20
Download 20 pages 51.95 Kb
Page 9
Image 9

Table 2.

Vo,set

Rset (k ) R33

Recommend Value, R//R

0.7525

Open

Open

1.2

22.464

23.7k//432k

1.5

13.047

14.0k//191k

1.8

9.024

9.53k//169k

2.5

5.009

5.23k//118k

3.3

3.122

3.16k//261k

5.0

1.472

1.5k//78.7k

Test

1.Put the resistor to program the desired output voltage set point by follow Table 1 and Table 2 for the standard output.

2.Set the input voltage to the desired operating level while monitoring DVM2.

3.Turn on the fan.

4.Set the enable switch SW2 to the “ON” position to enable the converter.

5.Adjust the output load across the converter’s operating load range.

6.Note the output voltage over the full range of the operating load range (please refer to the data sheet for the detailed specification).

(2)Output Voltage Set-Point Adjustment by external voltage source

For DNS series, trim to Vo,set using an external voltage source, connect it between the TRIM pin and GND pin. Please refer to the Table 3 and Table 4 as below for the appropriate Vout. The value of Vtrim is specified as follows:

For DNS04xx series

Vtrim = 0.7 − 0.1698 ⋅ (Vout − 0.7525)

For example, to program the output voltage of a DNS04 module to 3.3 Vdc, Vtrim is

calculated as follows:

 

 

 

Vtrim = 0.7 − 0.1698 ⋅ (3.3 − 0.7525) = 0.267V

 

 

Table 3. : Vo,set adjustment range by use of external voltage source.

 

 

Normal

 

 

 

Product Part

Output Set

Vrim (V)

 

 

Voltage

 

 

 

 

 

 

 

(Vdc)

 

 

 

 

0.7525

Open

 

 

 

1.2

0.6240

 

 

 

 

 

 

 

DNS04S0A0R06P A/B/C

1.5

0.5730

 

 

DNS04S0A0R06N A/B/C

1.8

0.5220

 

 

 

2.5

0.4030

 

 

 

 

 

 

 

 

3.3

0.2670

 

9

Page 9
Image 9
Delta Electronics DNS SIP Series manual For DNS04xx series, Vtrim = 0.7 − 0.1698 ⋅ Vout