8.2.4 Output Voltage Set-point Programming

(1) Output Voltage Set-Point Adjustment by external resistor

Output Voltage Set-point Programming can be carried out by using the external program resistor connect between TRIM pin to ground to set output voltage set-point from 0.75Vdc to 5Vdc, the location can refer to the Evaluation Board Schematic (please refer to the data sheet for more detailed specification). These test functions are divided into two types,

Rset of DNS04R series can be calculated by using the following equation:

Rset

21070

 

 

=

 

 

− 5110

 

 

 

Vo − 0.7525

 

For example, to program the output voltage of the DNS04 module to 1.8Vdc, below is the calculation of Rtrim:

21070

 

 

 

Rset =

 

 

− 5110

= 15004

 

 

1.8 − 0.7525

 

 

The table 1 provides the Rset value required for some standard output and the location on the Evaluation board is R33.

Table 1.

 

 

 

Vo,set

Rset (k ) R33

Recommend Value, R//R

 

0.7525

Open

Open

 

1.2

41.973

44.2k//825k

 

1.5

23.077

23.7k//825k

 

1.8

15.004

15.4k//590k

 

2.5

6.947

7.15k//243k

 

3.3

3.160

3.16k//Open

Rset of the DNS12R series can be calculated by using the following equation:

Rset

10500

 

=

 

−1000

 

 

Vo − 0.7525

 

For example, to program the output voltage of the DNS12 module to 3.3Vdc, below is the calculation of Rset:

Rset

10500

 

 

=

 

 

−1000

= 3122

3.3 − 0.7525

 

 

The table 2 provides the Rset value required for some standard output. The location on the Evaluation board is R33.

8

Page 8
Image 8
Delta Electronics DNS SIP Series manual 10500