Delta Electronics E48SR12007 manual Output voltage noise and ripple measurement test Setup

Models: E48SR12007

1 15
Download 15 pages 30.47 Kb
Page 6
Image 6

ELECTRICAL CHARACTERISTICS CURVES

Vo(+)

0

Vo(-)

Copper Strip

10u

1u

SCOPE

RESISTIV

 

LOAD

 

 

 

Figure 12: Input reflected ripple current, is, through a 12µH source inductor at nominal input voltage and rated load current (20 mA/div, 2us/div)

0

Figure 13: Output voltage noise and ripple measurement test

setup

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

(V)

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

6

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

0

 

48V

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10

LOAD CURRENT (A)

Figure 14: Output voltage ripple at nominal input voltage and rated load current (Io=7A)(20 mV/div, 2us/div)

Load capacitance: 1µF ceramic capacitor and 10µF tantalum

capacitor. Bandwidth: 20 MHz. Scope measurements should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module.

Figure 15: Output voltage vs. load current showing typical current limit curves and converter shutdown points

E48SR12007_05222008

6

Page 6
Image 6
Delta Electronics E48SR12007 manual Output voltage noise and ripple measurement test Setup