Denso 36 operation manual Operating Modes, Emptying the Drain Tank If equipped

Models: 36

1 16
Download 16 pages 60.4 Kb
Page 10
Image 10
Operating Modes

Operating Modes

Offi ce Pro 36 operates in 2 modes, FAN Only and COOL. When in FAN Only mode, the unit circulates the surrounding air. When in COOL mode, the compressor is operational and cool air is circulated.

COOL Mode

Offi ce Pro 36 will operate in FAN Only mode for approximately 120 seconds before the compressor engages. (Time delay setting is 120 ±15 seconds.)

Temperature Control

The room temperature thermistor allows the unit to switch automatically between COOL and FAN Only modes. This is dependent upon inlet air temperature versus SET POINT temperature.

Fan Mode Control DIP Switch

The Fan Mode Control DIP Switch determines whether the FAN will continue to oper- ate or stop when the compressor cycles off. (SET POINT temperature equals inlet air or room temperature.) The unit has been preset at the factory for continuous fan operation.

Temperature Scale Display DIP Switch

The Temperature Scale Display DIP Switch changes the temperature(s) that are displayed to either °C or °F. The unit has been preset from the factory to display the temperature(s) in °F.

NOTE: If you wish to change the fan mode operation (COOL [OPERATE to

COOL [STOP), and/or the Temperature Scale Display (°F to °C), contact your Movin-

Cool reseller.

Emptying the Drain Tank (If equipped)

During COOL mode, condensate will accumulate in the drain tank. When the drain tank becomes full, the FULL TANK LED will fl ash and the unit will shut off automatically.

NOTE: If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off. If a pro-

gram is running, you must first press the Program

RUN button.

Open the front panel.

Pull the drain tank from the unit.

Remove the cap and empty the drain tank.

Replace the cap and return the drain tank to the unit.

Close the drain tank lid.

If the Program RUN LED is fl ashing, press the

COOL ON/OFF button to continue running the program. If the Program RUN LED is illuminated continuously, no further steps are necessary. If no program exists or the program was deacti- vated, press the COOL ON/OFF button to restart the unit.

7

Page 10
Image 10
Denso 36 operation manual Operating Modes, Emptying the Drain Tank If equipped