Drain Pump (Optional)

A drain pump allows continuous operation and eliminates the need for drain tanks.

When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and

discharges the water.

B

A

• When the water level drops below level (B), the

 

drain pump will stop.

 

 

NOTE:

 

 

If for any reason the water level exceeds that of level (A) in the pump reservoir, an overflow

Drain Switch will stop the compressor operation.

If the Fan Mode Control DIP Switch (see pg.5) has been set operate from the STOP position,

the Fan will also turn off while the drain pump is discharging water.

DAILY INSPECTION & MAINTENANCE

Emptying the Drain Tank

To empty the drain tank, refer to instructions, page 14.

Cleaning the Air Filters

Clean the air fi lters once a week. If the unit is used in a dusty environment, more frequent cleaning may be required.

A dirty air fi lter reduces air output resulting in a decrease of the cooling capacity.

Filter Removal Method

Turn the unit off, by pressing the COOL ON/OFF button. If a program is running, you must fi rst press the Program RUN button.

Remove the 2 air fi lters.

NOTE: To remove the filters from the Office Pro 36, open the front panel and side

panel filter doors. Unclip the wire frame and remove filter.

 

VELCRO

CLIP

ATTACHMENTS

 

FILTER

WIRE FRAME

CLIP

FILTER

8

Page 11