55
Chapter 2. Getting Started the BHT-7000 and System Mode
[4.5-2] Setting the communications parameters for the direct-connectinterface
Selecting "2:CONNECTOR" on the SET COMMUNI-
CATION menu calls up the screen shown at left.
1 PARAMETER: Switches to the commu-
nications parameters set-
ting screen.
2 PROTOCOL: Switches to the commu-
nications protocol screen.
Select a desired screen by using the numerical
keys or * and * keys, and then press the
ENT key.
To return to the SET COMMUNICATION menu,
press the C key.
(1) Communications parameters setting screen
Selecting "1:PARAMETER" on the SET CONNEC-
TOR screen calls up the screen shown at left.
Highlighted is the current setting.
1 TRANSMIT SPEED: Sets the transmission
speed.
2 PARITY BIT: Sets the vertical parity:
none, odd, or even.
3 DATA: Sets the character length.
4 STOP: Sets the stop bit length.
Select a desired item by using the numerical keys
or * and * keys. Then select a desired set-
ting by using the * and * keys.
To return to the SET CONNECTOR screen, press
the C key.
If the BHT-Ir protocol has been selected, the

parity bit, character length, and stop bit length

settings will be ignored.

SET CONNECTOR
1:PARAMETER
2:PROTOCOL

SET PARAMETER

< CONNECTOR >

1:TRANSMIT SPEED:

300 600 1200 2400

4800 9600 19200

38400 57600 115200

2:PARITY BIT : N O E

3:DATA:7 8 4:STOP:1 2

NOTE
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , ,
, and keys, respectively