Desa 101811-01C.pdf installation manual Continued, Installing To Wall, Thermostat Sensing Bulb

Models: 101811-01C.pdf

1 32
Download 32 pages 56.26 Kb
Page 10
Image 10
Continued

INSTALLING TO WALL

Continued

10

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 30. If planning to use fan, locate heater near an electrical outlet.

CEILING

 

36"

6"

Minimum

 

Minimum

 

From

 

Sides Of

 

Heater

 

Left

Right

Side

Side

 

3" Minimum To Top Surface

FLOOR

Of Carpeting, Tile Or Other

Combustible Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

THERMOSTAT SENSING BULB

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Locating Thermostat Sensing Bulb

1.Remove front panel of heater (see Figure 7, page 11).

2.Locate thermostat sensing bulb just under burner assembly.

IMPORTANT: Attach thermostat sensing bulb to back of heater for proper opera- tion.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Thermostat

Sensing Bulb

THERMOSTAT SENSING BULB Clamp

Figure 5 - Attaching Thermostat Sensing Bulb

101811

Page 10
Image 10
Desa 101811-01C.pdf installation manual Continued, Installing To Wall, Thermostat Sensing Bulb