Desa 101811-01C.pdf installation manual Inspecting Burner, Pilot Flame Pattern

Models: 101811-01C.pdf

1 32
Download 32 pages 56.26 Kb
Page 20
Image 20
INSPECTING BURNER

INSPECTING BURNER

20

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Thermocouple

Pilot Burner

 

Figure 19 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

 

Figure 20 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 19).

see Troubleshooting, pages 22 through 25

101811

Page 20