Continued
TROUBLE- SHOOTING
Item | How Often | How To |
Spark plug | Clean and regap every 600 | See Spark Plug, pages 12 and 13. |
| hours operation or replace |
|
| as needed. |
|
Fan blades | Clean every season or as needed. See Fan, page 19. | |
Motor | Not required/permanently lubricated |
WARNING
WARNING ICONG 001
Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
OBSERVED FAULT
Heater ignites, but
POSSIBLE CAUSE
Wrong pump pressure
Dirty air output, air intake, and lint filters
Dirty fuel filter
REMEDY
See Pump Pressure
Adjustment, page 14.
See Air Output, Air Intake and Lint Filters, page 14.
See Fuel Filter, pages 10 and 11.
Dirt in nozzle | See Nozzle, pages 15 thru 17. |
Dirty photocell lens | Clean photocell lens. |
Bad | Replace |
Heater will not ignite, but motor runs for a short period of time.
Wrong pump pressure | See Pump Pressure |
| Adjustment, page 14. |
Carbon deposits on spark | See Spark Plug, pages 12 |
plug and/or improper gap | and 13. |
Dirty fuel filter | See Fuel Filter, pages 10 |
| and 11. |
Dirt in nozzle | See Nozzle, pages 15 thru |
| 17. |
Water in fuel tank | Drain and flush fuel tank |
| with clean kerosene. See |
| Storing, Transporting, or |
| Shipping, page 8. |
WARNING ICONG 001 WARNING: High voltage! | |
Electronic ignitor not | Make sure electronic |
grounded (earthed) | ignitor mounting is tight. |
Bad electronic ignitor | Replace electronic ignitor. |
Motor does not start | Reset | |||
when heater is |
| button, see Figures 6 thru | ||
plugged in, fan |
| 8, pages 7 and 8. | ||
rotates slowly or | Binding pump rotor | If fan is hard to turn, see | ||
does not turn. | ||||
| Pump Rotor, page 18. | |||
|
| |||
|
|
|
| |
|
|
| 9 | |
|
|
|
|
099623