OWNER’S MANUAL
SERVICE PROCEDURES
Continued
Nozzle
Plug
Burner
Head
Figure 9 - Replacing Nozzle
Pump Pressure Adjustment
Spark
Plug
Spark
Solenoid Plug
Valve Wire
Fuel
Line
PUMP
(Procedure if Pump is Binding)
1.Remove upper shell (see page 10).
2.Loosen hex screw on flange clamp at rear of motor with 5/16"
3.Turn fan with hand (see Figure 12).
4.If fan turns freely, tighten screw on flange clamp.
5.If fan does not turn freely, replace pump.
6.Replace upper shell.
Hex Screw
On Flange
Clamp
1.Remove pressure gage plug from fuel pump port marked “GAGE.”
2.Install accessory pressure gage (part number M4574) to fuel pump port marked “GAGE” (see Figure 10).
Pressure
Gage
3.Start heater (see Operation, page 5). Allow motor to reach full speed.
4.Adjust pressure. Use small flat blade screwdriver to turn slotted screw at fuel pump port marked “PRESS ADJ.” Turn screw clockwise to increase pressure. Turn screw counterclockwise to de- crease pressure. See specifications at right for correct pressure for each model.
5.Stop heater (see page 5).
6.Remove pressure gage. Replace pres- sure gage plug in fuel pump port marked “GAGE.”
Figure 11 - Location of Screw on Flange Clamp
Fuel Pump Port | Fuel Pump Port |
Marked “PRESS | |
Marked “GAGE” | ADJ” |
Model | Pump Pressure |
350,000 Btu/Hr | 100 PSI |
600,000 Btu/Hr | 110 PSI |
Figure 10 - Adjusting Pump Pressure
Figure 12 - Turning Fan with Hand
Continued
099507 | 11 |