Desa BHDV41N/P, BHDV37N/P installation manual Pressure Testing Fireplace Gas Connections

Models: BHDV41N/P BHDV37N/P HDV37N/P HDV41N/P

1 44
Download 44 pages 36.67 Kb
Page 20
Image 20

® (B)HDV37N/P AND (B)HDV41N/P

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close manual shutoff valve (see Fig- ure 38).

2.Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air.

3.Check all joints from propane/LP sup- ply tank or gas meter to manual shutoff valve (see Figure 39 for propane/LP or Figure 40 for natural). Apply commer- cial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1.Open manual shutoff valve (see Fig- ure 38).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natu- ral gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 39 for propane/LP or Figure 40 for natural). Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fire- place, pages 26 through 28). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 26).

Manual

Open

Shutoff

 

Valve

 

Closed

Figure 38 - Manual Shutoff Valve

Propane/LP Supply

Tank

Manual

Shutoff Valve

Gas Valve

Figure 39 - Checking Gas Joints for Propane/LP Gas Fireplace

Manual

Shutoff Valve

Gas Meter

Gas Valve

Figure 40 - Checking Gas Joints for Natural Gas Fireplace

20

104558

Page 20
Image 20
Desa BHDV41N/P, BHDV37N/P Pressure Testing Fireplace Gas Connections, Close manual shutoff valve see Fig- ure

BHDV41N/P, BHDV37N/P, HDV37N/P, HDV41N/P specifications

The Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P are modern heating units designed to deliver efficient warmth and comfort in various residential and commercial spaces. These models are noted for their advanced features and technologies, which combine functionality and aesthetics.

One of the main features of these units is their energy efficiency. They utilize state-of-the-art technology to provide warmth while minimizing energy consumption. This makes them an environmentally friendly choice, ensuring that homeowners can enjoy a cozy atmosphere without significantly increasing their energy bills.

The design of the Desa series models is characterized by their sleek and attractive appearance. They are available in various finishes, allowing homeowners to choose a design that complements their interior décor. This not only enhances the aesthetic appeal of the room but also ensures that the heating unit blends seamlessly into the space.

Another significant characteristic of the Desa models is their versatile heating capabilities. They can accommodate a variety of room sizes, providing adequate heat regardless of the environment. Whether used in larger living areas or smaller spaces, these units are engineered to maintain a consistent and comfortable temperature.

The units come equipped with user-friendly controls, allowing for easy adjustments and optimal temperature settings. Many of the models feature programmable thermostats, enabling users to schedule heating cycles according to their lifestyles. This contributes to increased comfort and further adds to energy savings.

Safety is also a primary concern with the Desa heating units. They come with built-in safety features, such as automatic shut-off mechanisms and advanced flame sensors. These safety measures ensure peace of mind while using the units, safeguarding against potential hazards.

Additionally, the units are designed for easy installation and maintenance. Their straightforward installation process is complemented by durable construction, which minimizes the likelihood of breakdowns. Regular maintenance is simplified, allowing users to keep their heating systems in excellent working condition without significant effort.

In summary, the Desa HDV41N/P, HDV37N/P, BHDV37N/P, and BHDV41N/P heating units combine sophisticated technology, aesthetic design, versatility, user-friendly controls, safety features, and low maintenance requirements. They stand out as a superior choice for anyone looking to enhance their indoor climate while being mindful of energy consumption and design aesthetics.