1. After lighting, let pilot flame burn for

about one minute. Turn gas control

knob on the control valve to ON po-

sition. Turn variable control knob

anywhere between HI and LO. Slide

the selector switch to the REMOTE

position. Note: The burner(s) may

light if hand-held remote ON button

was on when selector switch was last

turned off. You can now turn the

burner(s) on and off with either op-

tional hand-held remote control unit.

IMPORTANT: Do not leave the se-

lector switch in the REMOTE posi-

tion when the pilot is not lit. This will

drain the battery.

IMPORTANT: Be sure to press the

ON/OFF buttons on the hand-held

remote control unit for up to 3 sec-

IMPORTANT: The hand-held re- mote control unit must be near the heater but not extremely close to it. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.

3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used.

4.To turn the burner(s) off when oper- ating in the manual mode, press the OFF button. If operating in the auto mode, press the MAN button, then press the OFF button. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the gas con- trol knob on the heater to the OFF position or set selector switch to OFF position.

Blower Control Knob Variable

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

Both the GA3700 manual blower and the DA3610T thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for DA3610T Only: If you are using DA3610T blower with optional ther- mostat (wall mount or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot

onds to assure proper operation.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the

(Optional Accessory)

OFF

ON

Control Knob

position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air

burner(s) on and off. When turning burner(s) off, the pilot will remain lit.

GHRCT Series Operation:

2b. Select the MAN (manual) or AUTO button on the hand-held remote con- trol unit (see Figure 59).

In manual mode, turn burner(s) on

or off by pressing the ON or OFF

buttons on the hand-held remote

control unit.

 

 

N

 

L

 

 

 

O

 

O

I

ON OFF REMOTE

T

F

O

H

O

 

 

 

 

F

 

 

 

 

LIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Control

Control Selector Switch in Knob in On

Remote Position (Optional Position

Remote Control)

Figure 58 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

• In auto mode, the room tempera-

ture is controlled by the thermo-

stat in the hand-held remote con-

trol unit. To increase the room tem-

perature, press the top arrow of the

TEMP button. To lower the room

temperature, press the bottom ar-

row of the TEMP button. At higher

settings the heater will run more.

IMPORTANT: This remote control

has been specially engineered to

take an air temperature sample

Shows Temperature Setting

Allows Burners to be Turned On and Off with the Hand-Held Remote Unit.

The Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected.

HI

TEMP

MAN LO ON

AUTO OFF

STATUS

Increases Room Temperature

Decreases Room Temperature

Turns Burners On and Off

Shows Current Operation Mode

every 5.5 minutes in the auto mode.

It will not respond immediately to

the temperature setting being

turned up or down.