Air Output, Air Intake, and Lint Filters

1.Remove upper shell (see page 10).

2.Remove fi lter end cover screws using 5/16" nut- driver.

3.Remove fi lter end cover.

4.Replace air output and lint

lters.

5.Wash or replace air intake

lter (see Preventative Maintenance Schedule, page 8).

6.Replace fi lter end cover.

7.Replace fan guard and upper shell.

IMPORTANT: Do not oil

fi lters.

Pump Pressure

Adjustment

1.

Remove pressure gauge

 

plug from fi lter end cover.

2.

Install accessory pressure

 

gauge (part number

Air Intake Filter

 

Filter End

 

Cover

Fan Guard

 

Lint Filter

 

Air Output

125 AIR FILTER REMOVAL

Filter

PFA/P 046

Figure 9 - Air Output, Air Intake, and Lint Filters

Pressure

HA1180).

Gauge

Relief

3.

Start heater (see Operation,

 

page 7). Allow motor to

 

reach full speed.

4.

Adjust pressure. Turn relief

 

valve to right to increase

Plug

Valve

pressure. Turn relief valve

to left to decrease pressure.

Set pump pressure at 4 psi.

5. Remove pressure gauge.

Replace pressure gauge

plug in fi lter end cover.

Figure 10 - Pressure Gauge Plug Removal

Pressure

Gauge

Figure 11 - Adjusting Pump Pressure

11

 

 

Page 11
Image 11
Desa BV125EDI owner manual Air Output, Air Intake, and Lint Filters, Pump Pressure Adjustment