DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = _________________ cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

____________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater

 

______________ Btu/Hr

 

 

 

 

Gas water heater*

 

______________ Btu/Hr

Example:

 

 

 

Gas furnace

 

______________ Btu/Hr

 

 

 

 

Gas water heater

 

40,000

Btu/Hr

Vented gas heater

 

______________ Btu/Hr

 

 

 

+

 

 

 

Vent-free heater

39,000

Btu/Hr

Gas fireplace logs

 

______________ Btu/Hr

 

 

=

 

 

 

Total

79,000

Btu/Hr

Other gas appliances* +

______________ Btu/Hr

 

 

 

 

 

 

 

 

Total

=

______________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________________ Btu/Hr (maximum the space can support)

_________________ Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support) 79,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or applicable local codes.

Continued

104340

5

Page 5
Image 5
Desa CGD3930NT, CCL3924NT, CY3124N, CY2718N AIR for Combustion Ventilation, Determining FRESH-AIR Flow for Heater Location

CY2718N, CY3124N, CGD3930NT, CCL3924NT specifications

Desa CCL3924NT, CGD3930NT, CY3124N, and CY2718N are innovative heating appliances designed to enhance comfort while promoting energy efficiency. Each model has its unique features and technologies that cater to diverse heating needs in residential and commercial settings.

The Desa CCL3924NT is a powerful, gas-fired heater that boasts an efficient heating capacity. This model is particularly favored for its ability to deliver warmth quickly, thanks to its advanced combustion technology that ensures optimal fuel usage. The CCL3924NT incorporates a user-friendly digital thermostat, enabling precise temperature control, which not only enhances comfort but also contributes to energy savings. Additionally, the unit has a sleek design, making it a versatile choice for various interior styles.

Next, the CGD3930NT represents a robust and efficient design optimized for large spaces. Equipped with a high output capability and an adjustable burner, it allows for customizable heating solutions. One of its notable features is the built-in safety mechanisms that include an automatic shut-off in case of overheating, ensuring peace of mind for users. The CGD3930NT is easy to install and maintain, further reinforcing its reputation as a reliable heating solution.

The CY3124N model stands out for its advanced technologies such as infrared heating. This model utilizes infrared technology to provide direct heat to objects and people rather than just warming the air, resulting in immediate comfort. The CY3124N is compact, making it an ideal choice for smaller rooms or spaces needing supplementary heating. Its energy-efficient operation helps reduce utility costs while promoting an environmentally friendly heating solution.

Lastly, the CY2718N is known for its flexibility and versatility. This model combines both portability and efficiency, featuring wheels for easy movement from room to room. The CY2718N is equipped with a multi-function control panel, allowing users to set timers, adjust heat settings, and select operation modes according to their specific preferences. This model is particularly popular among those looking for a temporary heating solution without compromising on performance.

In conclusion, Desa CCL3924NT, CGD3930NT, CY3124N, and CY2718N offer diverse features, advanced technologies, and unique characteristics that cater to various heating requirements. Their commitment to efficiency and user comfort makes them excellent choices for anyone in need of effective heating solutions.