TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Heater produces unwanted 1.

Heater burning vapors from

odors

paint, hair spray, glues, clean-

 

ers, chemicals, new carpet,

 

etc. (See IMPORTANT state-

 

ment above)

2.

Low fuel supply (propane/LP

 

only)

3.

Gas leak. See Warning

 

statement at top of page

1.Open window to ventilate room. Stop using odor caus- ing products while heater is running

2.Refill supply tank (propane/ LP only)

3.Locate and correct all leaks (see Checking Gas Connec- tions, page 13)

Heater shuts off in use (ODS

1. Not enough fresh air is avail-

1.

Open window and/or door for

operates)

 

able

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

3.

ODS/pilot is partially

 

pane/LP gas company

 

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 19)

 

 

 

 

Gas odor even when control knob

1. Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

2.

Control valve defective

 

tions, page 13)

 

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between con-

 

 

trol valve and burner

 

2.

Gas leak. See See Warn-

 

 

ing statement at top of

 

 

page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, page 13)

Log set cycles to pilot, but room

1. Thermostat sensing bulb

1. Reposition thermostat sensing

temperature drops to a lower than

needs to be repositioned

bulb (see Optional Position-

ideal level before log set comes

 

ing of Thermostat Sensing

back on

 

Bulb, page 24)

113183-01A

www.desatech.com

23

Page 23
Image 23
Desa CDR3924PT installation manual Gas leak. See Warning

CDR3924PT specifications

Desa CDR3924PT is an advanced digital control thermostat designed for precise temperature management in residential and commercial settings. Its sleek design and intuitive interface make it a popular choice among homeowners and professionals alike, contributing to enhanced comfort and energy efficiency in various environments.

One of the standout features of the CDR3924PT is its programmable functionality. Users can set different temperature schedules for weekdays and weekends, allowing for tailored climate control to match occupancy patterns. This flexibility can lead to significant energy savings, as the thermostat can automatically adjust heating and cooling based on user preferences and habits.

The unit is equipped with a high-resolution LCD display, offering clear visibility of current temperature settings and system status. Additionally, it provides real-time feedback on energy consumption, allowing users to monitor and adjust usage to optimize efficiency. The intuitive touch controls simplify navigation through the various settings, ensuring that users can easily customize their environment.

Integration with smart home technology is another key characteristic of the CDR3924PT. It is compatible with various home automation systems, enabling users to control their heating and cooling remotely via smartphone apps. This connectivity ensures that users can adjust settings from anywhere, giving them the ability to prepare their home environment before arriving or to fine-tune adjustments on the go.

The CDR3924PT utilizes advanced sensor technology to maintain accurate temperature control. It continuously measures ambient conditions, making real-time adjustments to ensure consistent comfort levels. The thermostat’s adaptive learning capabilities also allow it to learn user preferences over time, further enhancing its ability to maintain optimal conditions with minimal energy consumption.

For safety and convenience, the thermostat features a user-friendly installation process along with compatibility with various HVAC systems. It includes built-in safety protocols that prevent overheating or unwanted system failures, ensuring reliable operation over time.

In summary, the Desa CDR3924PT stands out in the market for its programmable features, smart home integration, and advanced sensor technology, making it a top choice for those seeking efficient and effective temperature management solutions. Whether for residential use or commercial applications, its reliable performance and user-friendly design make it a vital component in modern climate control systems.