INSTALLATION

Continued

INSTALLATION AND CLEARANCES FOR VENT-FREE OPERATION

WARNING: Maintain the minimum clearances. If pos- sible, provide greater clearances from floor, ceiling, and adjoining wall.

LOG SIZING REQUIREMENTS

Log

Minimum Firebox

 

 

 

 

 

 

Size

Height

Depth

Front

Rear *

 

 

 

Width

Width

24"

17"

14"

28"

20 1/4"

* Measured at 14" depth.

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127- listed manufactured fireplace, or listed vent-free firebox.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace cabinet (see Figure 4).

Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturerʼs instructions for minimum clearances to combustible materials.

B.Clearances from the top of the fireplace open- ing to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for

Combustible to Wall

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel proceed to If Using Mantel. If not using a mantel, follow the information on this page.

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncom- bustible material must extend at least 8" up. If noncombustible material is less than 12", you must install the fireplace hood accessory. See Figure 5 for minimum clearances.

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombus- tible material must extend at least 8 inches up. If noncombustible material is less than 12", you must install the fireplace hood accessory. Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 10, for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

12" or more

Noncombustible material

 

okay.

Between 8"

Install fireplace hood

and 12"

accessory (GA6050,

 

GA6052, or GA6053 see

 

Accessories, page 34).

Less than 8"

Noncombustible material

 

must be extended to at

 

least 8". See Between 8"

 

and 12", above. If you

 

cannot extend material,

 

you must operate heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

113183-01A

www.desatech.com

9

Page 9
Image 9
Desa CDR3924PT installation manual Installation and Clearances for VENT-FREE Operation, Rear, Width, 20 1/4

CDR3924PT specifications

Desa CDR3924PT is an advanced digital control thermostat designed for precise temperature management in residential and commercial settings. Its sleek design and intuitive interface make it a popular choice among homeowners and professionals alike, contributing to enhanced comfort and energy efficiency in various environments.

One of the standout features of the CDR3924PT is its programmable functionality. Users can set different temperature schedules for weekdays and weekends, allowing for tailored climate control to match occupancy patterns. This flexibility can lead to significant energy savings, as the thermostat can automatically adjust heating and cooling based on user preferences and habits.

The unit is equipped with a high-resolution LCD display, offering clear visibility of current temperature settings and system status. Additionally, it provides real-time feedback on energy consumption, allowing users to monitor and adjust usage to optimize efficiency. The intuitive touch controls simplify navigation through the various settings, ensuring that users can easily customize their environment.

Integration with smart home technology is another key characteristic of the CDR3924PT. It is compatible with various home automation systems, enabling users to control their heating and cooling remotely via smartphone apps. This connectivity ensures that users can adjust settings from anywhere, giving them the ability to prepare their home environment before arriving or to fine-tune adjustments on the go.

The CDR3924PT utilizes advanced sensor technology to maintain accurate temperature control. It continuously measures ambient conditions, making real-time adjustments to ensure consistent comfort levels. The thermostat’s adaptive learning capabilities also allow it to learn user preferences over time, further enhancing its ability to maintain optimal conditions with minimal energy consumption.

For safety and convenience, the thermostat features a user-friendly installation process along with compatibility with various HVAC systems. It includes built-in safety protocols that prevent overheating or unwanted system failures, ensuring reliable operation over time.

In summary, the Desa CDR3924PT stands out in the market for its programmable features, smart home integration, and advanced sensor technology, making it a top choice for those seeking efficient and effective temperature management solutions. Whether for residential use or commercial applications, its reliable performance and user-friendly design make it a vital component in modern climate control systems.