INSTALLATION

Continued

Option two: Have a licensed electrician con- nect blower to electrical source at junction box inside fireplace.

If using option one, have electrical outlet in- stalled at this time. If using option two, do not connect blower to electrical source at junction box until step 6.

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equip- ment shutoff valve. The flexible gas line must be the last item installed on the gas piping.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Attach flexible gas line to fireplace gas regula- tor. See Connecting Fireplace to Gas Supply, page 16.

6.If the optional blower has been installed con- nect blower to electrical source.

Option one: Route blower electrical cord through side or rear access door of fireplace. Plug electrical cord into electrical outlet.

Option two: Have a licensed electrician con- nect blower to electrical source at junction box inside fireplace.

7.Bend four nailing flanges on outer casing with pliers (see Figure 8).

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange.

9.Check all gas connections for leaks. See Checking Gas Connections, page 17.

IMPORTANT: When finishing your firebox, combustible materials such as wall board, gyp- sum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top of the firebox. Combustible materials should never overlap the firebox front facing. Firebox should not be placed on top of carpet or other kinds of fibrous material.

WARNING: Do not allow any combustiblematerialstooverlap the firebox front facing.

IMPORTANT: Noncombustible materials such as brick, tile, etc. may overlap the front facing, but should never cover any necessary openings like louvered slots.

WARNING: Do not allow non- combustible materials to cover any necessary openings like louvered slots.

WARNING: Never modify or cover the louvered slots on the front of the firebox.

WARNING: Use only non- combustible mortar or adhe- sives when overlapping the front facing with noncombustible facing material.

Nails or

Wood

Screws

Nailing

Flanges

Figure 8 - Attaching Fireplace to Wall

Studs

Mantel Clearances for Built-In Installation

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

10

www.desatech.com

113896-01B

Page 10
Image 10
Desa CF26NTA installation manual Attaching Fireplace to Wall Studs, Mantel Clearances for Built-In Installation

CF26NTA specifications

Desa CF26NTA is a highly versatile and innovative diesel generator designed to meet the power needs of various applications. With its robust construction and efficient performance, the CF26NTA serves as an ideal power solution for both residential and commercial use, particularly in regions where grid power is unreliable or unavailable.

One of the main features of the Desa CF26NTA is its powerful 26 kVA output, which provides ample energy to support multiple appliances and systems simultaneously. This generator is capable of handling the demands of larger homes, construction sites, and outdoor events, ensuring that essential functions are maintained even during power outages.

The CF26NTA utilizes advanced technology to provide reliable power while minimizing fuel consumption and emissions. Equipped with a high-efficiency diesel engine, this generator offers extended run times and an impressive fuel economy, making it a cost-effective choice for long-term power needs. The engine complies with stringent environmental regulations, ensuring that users can operate it with confidence regarding its impact on the environment.

Another notable characteristic of the Desa CF26NTA is its user-friendly control panel, which features easy-to-read gauges and indicators. This design allows operators to monitor essential parameters such as voltage, frequency, and fuel levels at a glance, facilitating efficient management of the generator's operation. Additionally, the generator is fitted with automatic voltage regulation (AVR) technology, providing stable power output and protecting connected devices from voltage fluctuations.

Portability is an essential aspect of the CF26NTA, as it is designed with a compact frame and integrated wheels for easy transportation. Whether moving it between job sites or relocating for outdoor events, users will appreciate the generator's ease of mobility without compromising its stability during operation.

The Desa CF26NTA is built to withstand the rigors of demanding environments. It features weather-resistant casing and a durable design that ensures longevity and dependability even in challenging conditions. Furthermore, its maintenance-friendly layout allows for easy access to key components, simplifying routine servicing and upkeep.

In summary, the Desa CF26NTA stands out with its robust power output, efficient diesel engine technology, user-friendly features, and portable design. It is an excellent choice for anyone in need of a reliable generator that combines performance with convenience, making it suitable for various applications, from home use to commercial settings.