Desa CF26NTA Continued, Installing Logs, Pressure Testing Heater Gas Connections

Models: CF26NTA

1 36
Download 36 pages 59.03 Kb
Page 18
Image 18
PRESSURE TESTING HEATER GAS CONNECTIONS

INSTALLATION

Continued

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open equipment shutoff valve (see Figure 24, page 17).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figures 25 and 26, page 17). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, page 19). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appli- ance, page 21).

8.Replace front panel.

INSTALLING LOGS

INSTALLING LOGS WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Figure 28 - Installing One-Piece Log set CAUTION: After installa- tion and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to HI, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contact- ing logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

Place one-piece log set on grate to fit as illustrated in Figure 27. Make sure back section of log set is seated into “U”-shaped cutout in center of chassis (see Figure 27). IMPORTANT: Make sure log does not cover any burner ports (see Figure 28).

 

One Piece

 

Log Set

 

Burner

 

“U”-shaped

Chassis

Cutout in

 

Chassis

Figure 27 - Installing One-Piece Log Set

Burner

One Piece Log Set

Ports

 

Figure 28 - Installing One-Piece Log set

(Top View)

18