INSTALLATION

Continued

3.Assemble trim kit. See Assembling Trim, page 11.

4.Place trim on the shoulder screws located on the side and top of the fireplace. Firmly snap the trim over the shoulder screws on fireplace (see Figure 14).

5.Place mantel base close to wall in desired fireplace location.

6.Install gas line. See Connecting To Gas Sup- ply, page 15

7.Carefully place fireplace on mantel base and center left to right. Check for gas leaks. See Checking Gas Connections, page 17.

8.Refer to instructions provided with the mantel for permanent attachment to wall.

9.Slide mantel around fireplace. Be careful not to damage wall or mantel.

10.Adjust assembly to remove any gaps. From back side of fireplace, attach two 2" wood screws through base mounting blocks at- tached to bottom sides of mantel into base (see instructions provided with mantel).

11.Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. See Figure 13 for screw hole location.

Mantel

Screw

Location

Figure 13 - Removing Hood

Shoulder

Screws

Assembled

Trim

Figure 14 - Attaching Trim to Fireplace

INSTALLING BLOWER ASSEMBLY GA3450T

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and danger- ous operation.

CAUTION: Verify proper op- eration after servicing.

Note: If you are using a mantel with your heater, use the following instructions. If your heater is built-in, see For Built-In Installation on page 14.

1.Screen and hood should be removed from fireplace (see page 9). Remove log set and set aside.

2.Install snap bushings found in hardware kit into both holes in rear of blower control shield (see Figure 15).

3.Make sure the wire harness is firmly con- nected to the terminals on the blower bracket assembly.

4.Note the wire locations on back of AUTO/ OFF/ON switch. Carefully remove red wire from the AUTO terminal and blue wire from the ON terminal. Black wire can remain on the middle or OFF terminal (see Figure 16, page 13).

5.Carefully disconnect green and white wires from power cord harness at their insulated connectors.

6.In top of the heater cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket as- sembly to the outer casing with 4 - #10 screws provided (see Figure 16, page 13).

7.Route the wire harness through the hole to the left side of heat deflector. Pull wire harness through lower opening to the left of the blower control shield. (see Figure 16, page 13).

Blower

 

Control

 

Shield

Snap

 

 

Bushing

Figure 15 - Installing Snap Bushings

12

www.desatech.com

113896-01B

Page 12
Image 12
Desa CF26NTA installation manual Installing Blower Assembly GA3450T, Removing Hood

CF26NTA specifications

Desa CF26NTA is a highly versatile and innovative diesel generator designed to meet the power needs of various applications. With its robust construction and efficient performance, the CF26NTA serves as an ideal power solution for both residential and commercial use, particularly in regions where grid power is unreliable or unavailable.

One of the main features of the Desa CF26NTA is its powerful 26 kVA output, which provides ample energy to support multiple appliances and systems simultaneously. This generator is capable of handling the demands of larger homes, construction sites, and outdoor events, ensuring that essential functions are maintained even during power outages.

The CF26NTA utilizes advanced technology to provide reliable power while minimizing fuel consumption and emissions. Equipped with a high-efficiency diesel engine, this generator offers extended run times and an impressive fuel economy, making it a cost-effective choice for long-term power needs. The engine complies with stringent environmental regulations, ensuring that users can operate it with confidence regarding its impact on the environment.

Another notable characteristic of the Desa CF26NTA is its user-friendly control panel, which features easy-to-read gauges and indicators. This design allows operators to monitor essential parameters such as voltage, frequency, and fuel levels at a glance, facilitating efficient management of the generator's operation. Additionally, the generator is fitted with automatic voltage regulation (AVR) technology, providing stable power output and protecting connected devices from voltage fluctuations.

Portability is an essential aspect of the CF26NTA, as it is designed with a compact frame and integrated wheels for easy transportation. Whether moving it between job sites or relocating for outdoor events, users will appreciate the generator's ease of mobility without compromising its stability during operation.

The Desa CF26NTA is built to withstand the rigors of demanding environments. It features weather-resistant casing and a durable design that ensures longevity and dependability even in challenging conditions. Furthermore, its maintenance-friendly layout allows for easy access to key components, simplifying routine servicing and upkeep.

In summary, the Desa CF26NTA stands out with its robust power output, efficient diesel engine technology, user-friendly features, and portable design. It is an excellent choice for anyone in need of a reliable generator that combines performance with convenience, making it suitable for various applications, from home use to commercial settings.