GE 10-95 CG warranty Wire Conduit Installation, Installation Instructions, Note Aluminum Wiring

Models: 10-95 CG

1 44
Download 44 pages 62.34 Kb
Page 38
Image 38
STEP 6

INSTALLATION INSTRUCTIONS

(continued)

STEP 6

3 WIRE CONDUIT INSTALLATION

Remove the 3 screws from the connector block. Insert bare wires between the connector block terminals and movable nuts. Tighten screws securely. Do not remove ground strap connection.

 

SCREW

 

CONNECTOR

 

BLOCK

 

TERMINAL

BARE

 

WIRE

 

MOVABLE

FLEXIBLE

NUT

CABLE

CONNECTOR

BLOCK

BARE

WIRE TIPS

BRACKET

CONDUIT

WARNING: CONNECTOR BLOCK IS APPROVED FOR COPPER WIRE CONNECTION ONLY. IF ALUMINUM WIRE IS USED, SEE NOTE BELOW.

NOTE: ALUMINUM WIRING

A.Do not connect Aluminum wire to connector block. Use copper building wire rated for the correct amperage and voltage to make 3 (three) 3 inch copper jumper wires. Connect wire as per Step 6 or 7 depending on number of wires.

B.Splice copper wires to aluminum wiring using special connector terminals designed and UL approved for joining copper to aluminum and follow the connector manufacturers recommended procedure closely.

Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.

STEP 7

4 WIRE CONDUIT INSTALLATION

Remove the 3 screws from the connector block. Remove the grounding strap from the connector block middle location and the screw connecting it to the frame of the range. Insert bare wires between the connector block terminals and movable nuts. Tighten screws securely. Attach ground wire to the frame of the range.

 

SCREW

 

CONNECTOR

 

BLOCK

 

TERMINAL

BARE

 

WIRE

 

MOVABLE

FLEXIBLE

NUT

CABLE

CONNECTOR BLOCK NOTE: ALUMINUM WIRING

BARE WIRE TIPS

BRACKET STEP 7

CONDUIT

WARNING: CONNECTOR BLOCK IS APPROVED FOR COPPER WIRE CONNECTION ONLY. IF ALUMINUM WIRE IS USED, SEE NOTE BELOW.

NOTE: ALUMINUM WIRING

A.Do not connect Aluminum wire to connector block. Use copper building wire rated for the correct amperage and voltage to make 3 (three) 3 inch copper jumper wires. Connect wire as per Step 6 or 7 depending on number of wires.

B.Splice copper wires to aluminum wiring using special connector terminals designed and UL approved for joining copper to aluminum and follow the connector manufacturers recommended procedure closely.

Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.

38

Page 38
Image 38
GE 10-95 CG warranty Wire Conduit Installation, Installation Instructions, Note Aluminum Wiring