Desa CF26NTA Continued, To Turn Off Gas To Appliance, Thermostat Control Operation

Models: CF26NTA

1 36
Download 36 pages 59.03 Kb
Page 20
Image 20
TO TURN OFF GAS

OPERATING FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Shutting Off Heater to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Shutting Off Burner Only (pilot stays lit) to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The ther- mostat will gradually modulate the heat output and flame height from higher to lower settings or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 19.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, page 19.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 31 shows a correct pilot flame pattern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 32

turn heater off (see To Turn Off Gas to Appli- ance, column 1)

see Troubleshooting, page 23

Note: The correct pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Thermocouple

 

Figure 31 - Correct Pilot Flame Pattern
(propane/LP ignitor shown)

Pilot Burner

Thermocouple

Figure 32 - Incorrect Pilot Flame Pattern

(propane/LP ignitor shown)

20

www.desatech.com

113896-01B

Page 20
Image 20
Desa CF26NTA Continued, To Turn Off Gas To Appliance, Thermostat Control Operation, Manual Lighting Procedure