INSTALLATION
Continued
For Built-In Installation
WARNING: A licensed elec- trician must connect the wiring harness to electrical supply following all local codes. Electri- cian must provide a clamp on the box cover to secure the wiring. Wiring should be routed through the bushing in the hole on the outer casing of heater.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS Thisapplianceisequippedwitha
1.Install a snap bushing found in hardware kit into one of the holes found on rear of blower control shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply.
2.Follow steps 2 through 6 in Installing Blower Assembly, page 12. Also remove black wire from middle/OFF switch terminal.
3.Remove black plastic strain relief and power cord from switch plate (see Figure 18). The power cord supplied will not be used in built- in installations. Pop in the plastic snap bushing found in hardware kit into the hole left by supply cord/strain relief.
4.A licensed electrician must follow the wiring diagram in Figure 19, page 15 to connect incoming electrical supply to fan kit wiring harness.
5.Test to make sure the blower is working properly.
6.Reinstall hood assembly (see page 12) and close lower louver door.
7.Place log set back into unit.
Blower Bracket
Assembly
Screw
Switch
Strain Wire
Relief Harness
Power
Cord
Blue
Switch
Plate
Red
Outlet Receptacle
Shield
Cover
Blower
Control
Shield
Clamp
Connector (not Wire
included) Harness
Figure 18 - Installing Blower Bracket Assembly
14 | www.desatech.com |