INSTALLATION
Continued
An optional blower kit is available from your dealer. See Accessories, page 32. If planning to use blower, locate fireplace near an electrical outlet.
Note: When installing fireplace directly on carpet- ing, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace.
CEILING
| 42" Minimum |
6" |
|
Minimum |
|
From |
|
Sides Of |
|
Fireplace |
|
Left | Right |
Side | Side |
FLOOR
0" Minimum Clearance To Top Surface Of Carpeting, Tile Or Other Combustible Material
Figure 4 - Mounting Clearances As
Viewed From Front of Fireplace Shown
Built In The Wall
CEILING
42"
Top OfMinimum Mantel Can
Be Flush
With Wall
| Right |
Left | Side |
| |
Side |
|
0" Minimum Clearance To Top Surface Of Carpeting, Tile Or Other Combustible Material
Figure 5 - Mounting Clearances As
Viewed From Front of Fireplace Shown
with Optional Mantel
BUILT-IN FIREPLACE
INSTALLATION
| Actual | Framing |
Height | 26" | 26 7/8" |
Front Width | 26 3/4" | 26 7/8" |
Depth | 9 1/2" | 10 1/2" |
Bottom | 3/4" | 3/4" |
1.Frame in rough opening. Use dimensions shown in Figure 6 for the rough opening.
If installing in a corner, use dimensions shown in Figure 7 for the rough opening. The height is 26 1/8" which is the same as the wall opening above.
2.An optional blower accessory is available (see Accessories, page 32). There are two options for connecting blower to electrical source.
Option one: Have a licensed electrician install a properly grounded,
101/2"
267/8"
3/4" Off
The Floor
267/8" Minimum
Figure 6 - Rough Opening for Installing
in Wall
365/8"
257/8"
267/8" 513/4"
Figure 7 - Rough Opening for Installing
in Corner
www.desatech.com | 9 |