Desa CF26PTA installation manual Installation

Models: CF26PTA

1 36
Download 36 pages 38.79 Kb
Page 15
Image 15
INSTALLATION

 

 

INSTALLATION

 

 

 

Continued

 

 

 

Fan Switch

 

 

 

(Auto/Off/On)

 

 

 

 

1 Auto

Thermostat

 

 

Off 2

 

 

Blue

 

 

3

Switch

 

 

 

 

 

(N.O.)

 

 

 

 

 

 

 

110/115

On

Blue Blower

 

 

 

 

 

V.A.C.

 

 

 

 

Motor

 

 

Black

Red

Red

 

 

 

 

Green

 

 

 

 

White

 

 

White

 

 

 

 

 

 

 

 

 

 

 

Green

 

Figure 19

- Wiring Diagram For Fan

 

 

Accessory Built-In Installation

CONNECTING TO GAS SUPPLY

Manual background WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

Manual background WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

Manual backgroundCAUTION:Neverconnectpro- pane/LP fireplace directly to the propane/LPsupply.Thisfireplace requires an external regulator (notsupplied).Installtheexternal regulator between the fireplace and propane/LP supply.

Manual background WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

sediment trap

tee joint

pipe wrench

test gauge connection *

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 32.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 20. Pointing the vent down protects it from freezing rain or sleet.

Manual background CAUTION: Use only new, black iron or steel pipe. In- ternally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.

Propane/LP

Supply Tank

External

Regulator

Manual backgroundManual background Vent

Pointing

Down

Figure 20 - External Regulator With Vent

Pointing Down

113896-01A

www.desatech.com

15

Page 15
Image 15
Desa CF26PTA installation manual Installation