Desa VS18NR, CFS18NR Continued, Connecting To Gas Supply, Installation Items Needed

Models: CFS18NR VS24NR VS30NR VS18NR

1 26
Download 26 pages 500 b
Page 11
Image 11
CONNECTING TO GAS

OWNER’S MANUAL

INSTALLATION

Continued

3.Mark screw locations through holes in front panel of base (see Figure 12). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

4.Remove heater base from fireplace.

5.Drill holes at marked locations using 3/16" masonary drill bit.

6.Attach base to fireplace floor using two masonry screws (in hardware package).

7.Connect to gas supply. See Connect- ing To Gas Supply.

Gas Control

Flexible Gas Hose (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

Masonry Screws

CONNECTING TO GAS

SUPPLY

NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 23.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

A.G.A. Design-Certified

Manual Shutoff Valve With

1/8" NPT Tap*

From

Gas Supply (5" W.C.** to 10.5" W.C.

Pressure)

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual backgroundCAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Manual background CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings.

Approved Flexible Gas Hose (if allowed by local codes)

Figure 12 - Attaching Base to Fireplace

Tee

 

Floor

Joint

 

Sediment

Pipe

3" Minimum

Trap

Nipple

 

 

 

 

Cap

 

Gas Control

Figure 13 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 23.

** Minimum inlet pressure for purpose of input adjustment.

Continued

 

 

103449

11

Page 11
Image 11
Desa VS18NR, CFS18NR, VS24NR VS30NR installation manual Continued, Connecting To Gas Supply, Installation Items Needed