OWNER’S MANUAL

INSTALLATION

Continued

MANTEL CLEARANCES

In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear- ances listed below, you will need a hood.

Determining Minimum Mantel Clearances

 

10"

 

8"

 

 

6"

 

 

2 1/2"

Minimum Non-

 

 

(A)

 

 

 

 

Combustible

 

 

 

 

 

Material

 

 

12"

 

 

 

 

 

 

 

Mantel Shelf

Underside of

Mantel Shelf

All minimum distances are in inches

20" 241/2" 271/2" 30"

Top of Fireplace

Opening

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Determining Minimum Mantel Clearance When Using a Hood

If minimum clearances in Figure 6 are not

Figure 6 - Minimum Mantel Clearances Without Using Hood

met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clear- ances shown in Figure 7 when using hood.

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

operate the logs only with the

 

flue damper open

raise the mantel to an accept-

12"

10"

8"

6"

2 1/2"

Minimum

Noncombustible

Material

Mantel Shelf

Underside of

Mantel Shelf

All minimum distances are in inches

8"

12"

15"

18"

20"

Min.

 

 

 

 

Top of Fireplace

Opening

able height

• remove the mantel

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum dis- tance of 14" to combustibles (see Fig- ure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combus- tible flooring (see Figure 9).

Hood (GA6050,

Distances to

GA6052 and

Underside of

GA6053)

Mantel

Figure 7 - Minimum Mantel Clearances When Using Hood

 

Combustible

 

14"

Material

 

 

Hearth

Min.

 

 

 

Combustible

 

 

Material

 

 

5"

 

Noncombustible

Min.

 

 

 

Material

 

Figure 8 - Minimum Fireplace Clearances

Figure 9 - Minimum Fireplace Clearances

If Installed at Floor Level

 

Above Combustible Flooring

Continued

103449

9

Page 9
Image 9
Desa CFS18NR, VS24NR VS30NR, VS18NR installation manual Floor Clearances, Determining Minimum Mantel Clearances