Desa VS18NR Desa International, Unvented Natural Gas Log Heater, Troubleshooting, Continued

Models: CFS18NR VS24NR VS30NR VS18NR

1 26
Download 26 pages 500 b
Page 20
Image 20
See Wiring Diagram, page 22

DESA INTERNATIONAL

UNVENTED NATURAL GAS LOG HEATER

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

One or both burners do not light after ODS/

1.

Inlet gas pressure is too low

1.

Contact local natural gas company

pilot is lit

2.

Burner orifice(s) clogged

2.

Clean burner(s) (see Cleaning and Main-

 

 

 

 

tenance, page 18) or replace burner

 

 

 

 

orifice(s)

 

3.

Mislocated crossover tube

3.

Contact qualified service person

 

4.

Burner orifice(s) diameter is too small

4.

Replace burner orifice(s)

 

5.

Remote selector in OFF position

5.

Put remote selector in ON position

 

6.

Wire disconnected from gas control

6.

See Wiring Diagram, page 22

 

 

 

 

 

Delayed ignition of one or both burners

1.

Manifold pressure is too low

1.

Contact local natural gas company

 

2.

Burner orifice(s) clogged

2.

Clean burner(s) (see Cleaning and Main-

 

 

 

 

tenance, page 18) or replace burner

 

 

 

 

orifice(s)

 

3.

Mislocated crossover tube

3.

Contact qualified service person

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 18) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas control defective

3.

Replace gas control

 

 

 

 

 

Yellow flame in front burner during burner

1.

Not enough air

1.

Check burner(s) for dirt and debris. If

combustion

 

 

 

found, clean burner(s) (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

2.

Gas control defective

2.

Replace gas control

 

 

 

 

 

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (pages 4 through 6)

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burners are lit

 

when burners are cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burners until air is removed

 

 

 

 

from line. Have gas line checked by lo-

 

 

 

 

cal natural gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see pages 7 through 9)

 

4.

Dirty or partially clogged burner orifice(s)

4.

Clean burners (see Cleaning and Main-

 

 

 

 

tenance, page 18) or replace burner

 

 

 

 

orifice(s)

 

 

 

 

 

White powder residue forming within burner

1.

When heated, vapors from furniture pol-

1.

Turn heater off when using furniture

box or on adjacent walls or furniture

 

ish, wax, carpet cleaners, etc. turn into

 

polish, wax, carpet cleaners, or similar

 

 

white powder residue

 

products

 

 

 

 

 

Remote does not function

1.

Battery is not installed. Battery power

1.

Replace 9-volt batteries in receiver and

 

 

is low

 

remote control

www.desatech.com

20

103449

Page 20
Image 20
Desa VS18NR Desa International, Unvented Natural Gas Log Heater, Troubleshooting, Continued, Observed Problem, Remedy