OWNER’S MANUAL

INSTALLATION

Continued

Gas Control

Flexible Gas Hose (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

sealant (resistant to propane/LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.

Propane Supply Tank

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

13.Pointing the vent down protects it from freezing rain or sleet.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Masonry Screw

Masonry Screw

 

Figure 12 - Attaching Base to Fireplace Floor

CONNECTING TO GAS SUPPLY

NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.

CAUTION: Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator be- tween the heater and propane supply.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer, see Figure 13)

piping (check local codes)

External

CAUTION: Use only new,

Regulator

black iron or steel pipe. Inter-

 

 

nally-tinned copper tubing may

 

be used in certain areas. Check

 

your local codes. Use pipe of 1/2"

 

diameter or greater to allow

 

proper gas volume to heater. If

 

pipe is too small, undue loss of

Vent

pressure will occur.

 

Pointing

Installation must include a manual shutoff

Down

valve, union, and plugged 1/8" NPT tap.

 

Figure 13 - External Regulator With Vent

Locate NPT tap within reach for test gauge

Pointing Down

hook up. NPT tap must be upstream from

 

heater (see Figure 14).

A.G.A. Design-Certified Manual

From External

Shutoff Valve With 1/8" NPT Tap*

Regulator

 

Approved Flexible Gas Hose

(11" W.C.** to

14" W.C. Pressure)

(if allowed by local codes)

 

Gas

Control

 

Tee

3" Minimum

Joint

Pipe

 

 

Nipple

 

Cap

Sediment Trap

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.

**Minimum inlet pressure for purpose of input adjustment.

Figure 14 - Gas Connection

Continued

104417

11

Page 11
Image 11
Desa VS18PRA, CFS18PRA, VS24PRA, VS30PRA installation manual Connecting to GAS Supply