DESA INTERNATIONAL
UNVENTED PROPANE/LP GAS LOG HEATER
OPERATING
HEATER
Continued
OPTIONAL REMOTE
OPERATION
Note: All remote control accessories must be purchased separately (see Accessories, page 25). Follow instructions included with the remote control.
Thermostat Control Operation
(Optional GHRCT Only) The thermo- stat control setting on the remote control unit can be set to any comfort level be- tween HI and LO. The burners will turn on and off automatically to maintain the comfort level you select. The ideal com- fort setting will vary by household de- pending upon the amount of space to be heated, the output of the central heating system, etc.
For wall thermostat operation, follow in- struction supplied with thermostat acces-
GHRC Operation:
2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.
GHRCT Operation:
2b. Select the MAN (manual) or AUTO button on the
•In manual mode, turn burners on or off by pressing the ON or OFF buttons on the
•In auto mode, the room tempera- ture is controlled by the thermo- stat in the
IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5
minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down. IMPORTANT: The
3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used when the sta- tus button is pressed.
4.To turn the burners off when operat- ing in the manual mode, press the OFF button. If operating in the auto mode, press the MAN button, then press the OFF button. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
sory GWMT1. For wall switch operation follow instructions supplied with GWMS2.
NOTICE: You must light the pilot before using the remote control unit. See Lighting Instructions on page 14.
1. After lighting, let pilot flame burn for |
about one minute. Turn control knob |
to ON position. Adjust flame adjust- |
ment knob anywhere between HI and |
LO. Slide the selector switch to the |
REMOTE position. Note: The burn- |
ers may light if |
Control Knob in On Position | Flame Adjustment Knob | ||||
|
|
|
| OL |
|
N |
|
| O |
|
|
O |
| F |
|
| |
|
|
|
| ||
T | F |
| HI | ON | |
OLIP |
|
|
| ||
|
|
|
|
| OFF |
|
|
|
|
| REMOTE |
Selector Switch in Remote Position
(Optional Remote Control)
Figure 23 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
button was on when selector switch |
was last turned off. You can now turn |
the burners on and off with the hand- |
held remote control unit. |
IMPORTANT: Do not leave the se- |
lector switch in the REMOTE or ON |
position when the pilot is not lit. This |
will drain the battery. |
IMPORTANT: Be sure to press the |
ON/OFF buttons on the hand held |
remote control unit for up to 3 sec- |
onds to assure proper operation. |
Shows Temperature Setting
Allows Burners to be Turned On and Off with the Hand- Held Remote Unit.
The log heater will automatically cycle between pilot and the heat setting that has been selected.
HI
TEMP
MAN LO ON
AUTO OFF
STATUS
Increases Room Temperature
Decreases Room Temperature
Turns Burners On and Off
Shows Current Operation Mode
Figure 24 - Thermostat Hand-Held Remote Control Unit Selections (GHRCT Only)