OWNER’S MANUAL
INSTALLATION
Continued
MANTEL CLEARANCES
In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet clearances listed in Figure 6 you will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).
Determining Minimum Mantel Clearance When Using a Hood
If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clear-
Mantel Shelf
10"
Underside of
| 8" |
|
|
|
|
|
| Mantel Shelf | ||
|
|
|
|
|
|
|
|
| ||
| 6" |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
| 2 1/2" |
|
|
|
|
|
| All minimum | ||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| distances are |
Minimum Non- |
|
| (A) |
|
|
|
|
|
| in inches |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
Combustible |
|
|
|
|
|
|
|
| Log Set | |
|
|
|
|
|
|
|
|
| ||
Material |
|
|
|
|
|
|
|
|
| |
|
| 12" | 18" |
| 20" | 22" | 24" |
| 24"/30" Models | |
|
|
|
|
| ||||||
|
|
| 8" | 14" |
| 16 3/4" | 18 1/2" | 20" |
| 18" Model |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
| Top of Fireplace | |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Opening | |
|
| Minimum Non- | Distances to |
|
|
| ||||
|
| Combustible |
| Underside of |
|
|
| |||
|
| Material Height | Mantel |
|
|
|
|
Figure 6 - Minimum Mantel Clearances Without Using Hood
Mantel Shelf
ances shown in Figure 7 when using hood.
NOTICE: If your installation does
12"
10"
8"
Underside of Mantel Shelf
not meet the minimum clearances shown, you must do one of the following:
•operate the logs only with the flue damper open
•raise the mantel to an accept- able height
•remove the mantel
FLOOR CLEARANCES
A. | If installing appliance on the floor level, |
| you must maintain the minimum dis- |
| tance of 14" to combustibles (see Fig- |
| ure 8). |
B. | If combustible materials are less than |
6"
2 1/2"
Minimum Non-
Combustible
Material
8"
Min.
Hood
(GA6050, GA6052, or GA6053)
12" | 15" |
|
|
Distances to Underside of Mantel
18"
All minimum distances are in inches
Log Sets
20" 18", 24",
& 30" Models
Top of Fireplace Opening
14" to the fireplace, you must install |
appliance at least 5" above the combus- |
tible flooring (see Figure 9). |
Figure 7 - Minimum Mantel Clearances When Using Hood
| Combustible |
|
|
14" | Material |
|
|
|
|
| |
Min. |
| Hearth | Combustible |
|
| ||
|
| 5" | Material |
| Noncombustible | Min. | |
| Material |
|
|
Figure 8 - Minimum Fireplace Clearances | Figure 9 - Minimum Fireplace Clearances | ||
If Installed at Floor Level |
| Above Combustible Flooring |
Continued
104417 | 9 |