Desa CFS18PRA Minimum Noncombustible Material Clearances, Heat Resistant Material A, Installation

Models: VS18PRA VS24PRA VS30PRA CFS18PRA

1 26
Download 26 pages 47.79 Kb
Page 8
Image 8
Minimum Noncombustible Material Clearances

DESA INTERNATIONAL

UNVENTED PROPANE/LP GAS LOG HEATER

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 10).

Minimum Noncombustible Material Clearances

If Not Using Mantel

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9, for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. If noncombustible mate- rial is less than 12", you must install the fireplace hood accessory (24" and 30" mod- els only). See Figure 5 for minimum clear- ances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

 

Material Distance (A)

Requirements for Safe Installation

12" or more

Noncombustible material OK.

Between 8" and 12"

Install fireplace hood accessory (GA6050, GA6052,

 

or GA6053 see Accessories, page 25).

Less than 8"

Noncombustible material must be extended to at

 

least 8". See Between 8" and 12", above.

Heat Resistant Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

8

104417

Page 8
Image 8
Desa CFS18PRA Minimum Noncombustible Material Clearances, Heat Resistant Material A, Desa International, Installation